With an industrial experience of 14 years, we have emerged as undisputed leaders of Solid State Relays, Melt Pressure Transducers, Melt Pressure Controllers, etc. Renowned for operational fluency, negligible maintenance, and longer service life, our range finds wide application in Plastic, Pet, Packaging, Printing, Sugar and Engineering Industries.
With the assistance of advanced testing facilities like calibrator, multi-meter, and vernier, we are able to offer range in line with international standards. The systematic and streamlined methodology allows us to cater to the client requirement in best possible manner. Our adherence to ethical business practices in our business activity enables us to be one of the trusted partners of our esteem clients based in India, U.K, Nigeria, and Nepal. TATA Auto, Gillette India Ltd, Pepsi Co, LG, and Samsung is few of the reputed patrons we have been serving ever since our inception.
Approx. Rs 2,000 / PieceGet Latest Price
Product BrochureProduct Details:Model No. | CH902 |
Size | 1/4 DIN |
Control Type | PID |
Input Type | RTD, Thermocouple |
Temperature Range | 0 - 50 Deg C |
Display Type | 4 Digit/7 Segment |
Voltage | 24 VAC/DC |
Frequency | 50 - 60 Hz |
digital PID temperature controller Specification:
Model Name |
1.Outline dimension | See the outline dimension picture | |
2.Control Mode | F:PID operation and auto calculating (reverse operation) | D:PID operation and auto calculating(Forward operation) |
W:eating/cooling PID operation and auto calculating(cooling water)*1 | A:heating/cooling PID operation and auto calculating(cooling water)*1 | |
3.Input mode | Refer to Input Range Table | |
4.Range Code | Refer to Input Range Table | |
5.First control output(OUT1) (Heating side) |
M: Relay contact output V: Voltage impulse output T: Thyratron output |
8: Current output(IC4-20mA) G: Thyratron driving triggering output |
6.Second control output( OUT2) (Cooling side)*2 |
No mark: when the control mode is F or D M: Relay contact output V: Voltage impulse output |
T: Thyratron output 8: Current output(IC 4-20mA) |
7.First alarm(ALM1) 8.Second alarm (ALM2)*2 |
N: no alarm A: Upper-limit bias alarm B: Lower-limit bias alarm C: Upper/lower limit bias alarm D: alarm in area E: Standby upper-limit bias alarm attached F: Standby lower-limit bias alarm attached G: Standby upper/lower limit bias alarm H: Upper-limit input value alarm |
J: lower-limit input alarm K: Standby upper-limit input alarm attached L: Standby lower-limit input alarm attached P: Heater breakage alarm(CTL-6)*3 S: Heater breakage alarm(CTL-12)*3 R: Control line breakage alarm *4 V: Upper-limit set value alarm W: Lower-limit set value alarm |
9.Communication*5 | N:No communication | 5:RS-485(two-wire system) |
10.Water-proof/dust-proof | N:no water-proof/dust-proof | 1:with water-proof/dust-proof |
Refer to Input Range Table |
Input type | Set range | Input type | Set range | |
Thermocouple Input(TC) | K | 0 to 1372°C(0 to 2502 F) | J | 0 to 1200°C(0 to 2192 F) |
R | 0 to 1769°C(0 to 3216 F) | S | 0 to 1769°C(0 to 3216 F) | |
B | 0 to 1820°C(0 to 3308 F) | E | 0 to 1000°C(0 to 1832 F) | |
N | 0 to 1300°C(0 to 2372 F) | T | -199.9 to +400.0°C(-199.9 to +752.0 F) | |
W5Re/W26Re | 0 to 2320°C(0 to 4208 F) | PL | 0 to 1390°C(0 to 2534 F) | |
L | 0 to 900°C(0 to 1652 F) | U | -199.9 to +600.0°C(-199.9 to +999.9 F) | |
RTD Input Pt | 100Ω(JIS/IEC) | -199.9 to +649.0°C (-199.9 to +999.9 F) |
JPt100Ω(JIS) | -199.9 to +649.0°C (-199.9 to +999.9 F) |
Voltage input | 0 to 5V DC | 1 to 5V DC | -1999 to +9999(programmable range) | |
Current input | 0 to 20mADC | 4 to 20mADC | -1999 to +9999(programmable range0) |
Additional Information:
Approx. Rs 20,000 / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Input | Single or three phase |
DYDAC TEMPERATURE AND POWER CONTROL PANELS
We are expert in designing Heating control Panels that are widely used for various applications in heat control processes. These are provided with Temperature Controllers, PID Temperature Controllers within the system. The excellent design and fabrication increases the accuracy and infallibility. Dydac brand control panels are designed and engineered to meet virtually every heating applications. Rating in size from 5KW to 500KW Control panel made from 14, 16 SWG CRCA sheet duly painted. All necessary component to be provided with the panels.Following are some of the Panels are being Manufactured by us
Approx. Rs 1.2 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Type | Automatic |
Usage | Industrial Heating Control |
Digit Display Size | Dual Display |
Power | 220V |
Dydac Controls offers a wide range of both standard and custom engineered Process Control Panels. From 100 watts to 500 KW's, Dydac Controls can build an SCR system to meet your needs. Dydac Controls standard line of SCR power control panels is engineered with safety and ease of installation in mind. The control panels are pre-wired and tested on name plate voltage. Customer needs only to install incoming power wires, outgoing heater wires, and thermocouple input connections. Standard panel sizes are 20, 30, 60, 100, 150, 200, 250, 350 and 400 Amps. 230 to 480VAC.
Standard features include:
Options include:
Standard SCR Power Control Panels:
Approx. Rs 50,000 / PieceGet Latest Price
Product Details:Minimum Order Quantity | 1 Piece |
Phase | Single Phase |
Application | Heating Solution |
Power | 220V |
Explore More Products
© Dydac Controls. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited